FBNJ Series Counter Flow Closed Circuit Cooling Tower
Cooling Water Flow: 8–1,000 m³/h
Fan Diameter: 0.8–6.5 m
Fan Power: 0.75–115 kW
Max Air Flow: 1,250,000 m³/h
Spray Pump Power: 0.55–15 kW × 2
Inlet/Outlet Pipe:...Add to Inquiry
FBFJ Series Single Inlet Composite Flow Closed Circuit Cooling Tower
Cooling Water Flow: 8–385 m³/h
Fan Diameter: 0.8 m–2 m
Fan Power (Single): 0.75 kW–15 kW
Max Air Flow (3 Fans): 492,800 m³/h
Spray Pump Power: 0.55 kW–7.5...Add to Inquiry
FBFJ Series Double Inlet Composite Flow Closed Circuit Cooling Tower
Cooling Water Flow: 54 to 725 m³/h
Coil Working Pressure: 1.0 MPa
Spray Pump Pressure: 0.2-0.3 MPa
Spray Pump Motor: 2.2 kW - 11 kW x 2 setup
Inlet/0utlet Pipe Size: DN100x2 to...Add to Inquiry
FCN Series Dry Wet Integrated Closed Cooling Tower
Cooling Water Flow: 50–2,000 m³/h
Fan Diameter (Max): Up to 10 m
Fan Power: 5–280 kW
Max Air Flow: 2,720,000 m³/h
Spray Pump: 3–27 kW × 2
Inlet/Outlet Pipe: DN100 × 2...Add to Inquiry
FCN Series Dry Wet Separated Closed Cooling Tower
Cooling Water Flow: 50–2,000 m³/h
Dimensions (Min): 2.6 m × 5.7 m × 3.8 m
Dimensions (Max): 13 m × 26 m × 9.5 m
Fan Diameter: 1.8–12 m
Fan Power: 6–280 kW
Air Flow...Add to Inquiry
FZN Series Composite Flow Evaporative Type Condenser
Cooling Water Flow: 54–725 m³/h
Dimensions (Min): 2.2 m × 4.6 m × 3.07 m
Dimensions (Max): 6.2 m × 10.8 m × 6.11 m
Fan Diameter: 2.0–5.2 m
Fan Power: 4–75 kW
Air Flow...Add to Inquiry
Closed Type Cooling Tower
Cooling Water Flow: 8–2,000 m³/h
Min Dimensions (L×W×H): 1.3 m × 1.5 m × 2.25 m
Max Dimensions: 13 m × 26 m × 9.5 m
Fan Diameter: 0.8–12 m
Fan Power: 0.75–280 kW
Air...Add to Inquiry
Induced Draft Cooler
Heat Exchange Area: 500 – 15,000 m² (Customizable)
Fan Diameter: 1.5m – 10m
Tube Material: Stainless steel or Copper
Design Pressure: Up to 45.0 MPa
Motor Protection: IP55...Add to Inquiry
Closed System Cooling Tower
Cooling Water Flow: 8–2,000 m³/h
Dimensions (Min): 1.3 m × 1.5 m × 2.25 m
Dimensions (Max): 13 m × 26 m × 9.5 m
Fan Diameter: 0.8–12 m
Fan Power: 0.75–270 kW
Air Flow...Add to Inquiry
Closed Cell Cooling Tower
Cooling Water Flow: 8–2,000 m³/h
Fan Diameter: 0.8–12 m
Fan Power: 0.75–270 kW
Air Flow Range: 9,600–2,950,000 m³/h
Spray Pump Power: 0.55–27 kW × 2
Pipe Size:...Add to Inquiry
Hybrid Flow Evaporative Condenser
Heat Rejection Capacity: 100 kW – 5,000 kW per cell
Spray Water Flow: 20 – 500 m³/h
Casing Material: Z700 Galvanized steel or SUS304/316L Stainless steel
Fan Type: Axial flow...Add to Inquiry
Adiabatic Cooling Towers
Cooling Capacity: 50 m³/h – 2,000 m³/h per module
Water Saving Rate: Up to 70% compared to open-loop towers
Structure Material: SUS304 Stainless steel or Galvanized steel...Add to Inquiry
China closed type cooling tower Manufacturers Factory Suppliers
We adhere to the quality concept that quality comes from technology and details, and strive to create the best quality closed circuit cooling tower, closed loop cooling tower, marley closed circuit cooling tower. Our advancement depends over the superior machines, exceptional talents and continually strengthened technology forces for closed type cooling tower. Our marketing and advertising campaigns reflect the core values of our company. In order to focus more on sales and production and implement independent system management of production and sales, our company employs domestic and foreign professionals with high salary and establishes a strong research and development team. Advanced production technology and full computerized control of key procedures ensure stable quality from the production process control. Our company has established partnerships with top shipping and logistics providers to deliver products efficiently and economically. Our company's corporate culture is to create the best space for career development for our employees and to work to build a harmonious relationship with all parties in society. Our staff is committed to delivering personalized service and expertise.WebClosed circuit cooling towers, There is no direct contact between the water to cool down and the air inside closed circuit cooling towers, but an additional heat exchanger is however used. Cooling...
WebClosed Type Cooling Tower, SCC Series, Features, Range from 8Ton to 2000Ton, Completely closed water circuit, stay away from contamination, High quality Aluminium coated steel plate outside frame,...
WebNWN-S series Full- Stainless Steel Closed Type Cooling Tower is type of NWN series counter flow closed cooling tower combined with multiple units is available, closed loop, clean medium, not easy...
WebIn a closed-loop cooling tower, two different cooling circuits are created, external and internal circuits. In external circuits cooling water is used to mix with atmospheric...
WebLoop Type. In addition to the draft and flow design, cooling towers can also be either closed or open loop. Open loop systems are enclosed structures which distribute warm water over a “fill” with...
WebOne particularly effective type of natural draft cooling tower is the hyperbolic cooling tower. These cooling towers use a chimney-stacking design to let the dry, cool outside air push the warm,...