Eliminator Cooling Tower
Water Catch Rate: 99.5–99.9%
Drift Loss: 0.0005–0.002%
National Standard Drift: 0.015%
Module Size: 500×500 mm or 1000×500 mm
Air Speed Range: 2.5–4.5 m/s
Pressure Drop: 10–35 Pa per module
Prevent Water from Escaping Your Tower
Our Eliminator Cooling Tower captures water droplets that would otherwise be carried toward the fan by airflow. Without an effective eliminator, water is lost, the ground becomes wet and slippery, and safety hazards increase. Our eliminator captures 99.5–99.9% of water droplets, resulting in a drift loss of only 0.0005–0.002%, compared to the national standard of 0.015%-7 to 30 times better. The Eliminator Cooling Tower is compatible with both cross-flow and counter-flow towers. Installed between the fill and the fan, air passes through S-shaped channels, causing water droplets to hit the walls and return to the tower.

High-Temperature Options for Industrial Applications
The standard material is PVC, suitable for -35°C to 70°C and with an oxygen index of 32, meaning it is non-flammable. For air temperatures above 70°C, use PP (up to 85°C). For very hot air up to 120°C, FRP is recommended. Blade spacing ranges from 20–30 mm; tighter spacing increases water capture but slightly reduces airflow. Recommended air velocity through the eliminator is 2.5–4.5 m/s, with a pressure drop of only 10–35 Pa per module, ensuring minimal additional fan load.

Tested for Real-World Performance
We test our eliminators according to GB/T 7190 and CTI STD-201 standards. At 3.5 m/s airspeed, water carryover remains below 0.001%. Detailed charts are provided, showing pressure drop and water catch rate across different air speeds. The Eliminator Cooling Tower comes with a 5-year warranty, ensuring it retains its shape and does not become brittle. As a Jiangxi Green Technology company, we have received awards for energy saving and emission reduction. Every drop of water saved benefits the environment and reduces your operating costs.
Product Specifications
|
Parameter |
Details |
|
Water Catch Rate |
99.5–99.9% |
|
Drift Loss |
0.0005–0.002% |
|
National Standard Drift |
0.015% |
|
Module Size |
500×500 mm or 1000×500 mm |
|
Air Speed Range |
2.5–4.5 m/s |
|
Pressure Drop |
10–35 Pa per module |
|
Material Options |
PVC (70°C), PP (85°C), FRP (120°C) |
|
Oxygen Index (PVC) |
≥32 (UL94 V-0) |
|
Blade Spacing |
20–30 mm |
|
Warranty |
5 years |
|
Certifications |
CTI, ASME, CQC |
FAQ