Hainan Haizhou Fluid Technology Co., Ltd.
Eliminator Cooling Tower
Eliminator Cooling Tower
Eliminator Cooling Tower suppliers

Eliminator Cooling Tower

Water Catch Rate: 99.5–99.9%
Drift Loss: 0.0005–0.002%
National Standard Drift: 0.015%
Module Size: 500×500 mm or 1000×500 mm
Air Speed Range: 2.5–4.5 m/s
Pressure Drop: 10–35 Pa per module

Send Inquiry
Description
Prevent Water from Escaping Your Tower

Our Eliminator Cooling Tower captures water droplets that would otherwise be carried toward the fan by airflow. Without an effective eliminator, water is lost, the ground becomes wet and slippery, and safety hazards increase. Our eliminator captures 99.5–99.9% of water droplets, resulting in a drift loss of only 0.0005–0.002%, compared to the national standard of 0.015%-7 to 30 times better. The Eliminator Cooling Tower is compatible with both cross-flow and counter-flow towers. Installed between the fill and the fan, air passes through S-shaped channels, causing water droplets to hit the walls and return to the tower.

product-800-800
High-Temperature Options for Industrial Applications

The standard material is PVC, suitable for -35°C to 70°C and with an oxygen index of 32, meaning it is non-flammable. For air temperatures above 70°C, use PP (up to 85°C). For very hot air up to 120°C, FRP is recommended. Blade spacing ranges from 20–30 mm; tighter spacing increases water capture but slightly reduces airflow. Recommended air velocity through the eliminator is 2.5–4.5 m/s, with a pressure drop of only 10–35 Pa per module, ensuring minimal additional fan load.

product-800-800

 

Tested for Real-World Performance

 

We test our eliminators according to GB/T 7190 and CTI STD-201 standards. At 3.5 m/s airspeed, water carryover remains below 0.001%. Detailed charts are provided, showing pressure drop and water catch rate across different air speeds. The Eliminator Cooling Tower comes with a 5-year warranty, ensuring it retains its shape and does not become brittle. As a Jiangxi Green Technology company, we have received awards for energy saving and emission reduction. Every drop of water saved benefits the environment and reduces your operating costs.

 

Product Specifications

 

Parameter

Details

Water Catch Rate

99.5–99.9%

Drift Loss

0.0005–0.002%

National Standard Drift

0.015%

Module Size

500×500 mm or 1000×500 mm

Air Speed Range

2.5–4.5 m/s

Pressure Drop

10–35 Pa per module

Material Options

PVC (70°C), PP (85°C), FRP (120°C)

Oxygen Index (PVC)

≥32 (UL94 V-0)

Blade Spacing

20–30 mm

Warranty

5 years

Certifications

CTI, ASME, CQC

 

FAQ

 

Can I install this on an existing tower?

Yes. Installation is simple. Modules are available in 500×500 mm or 1000×500 mm sizes and can be cut with a knife to fit your tower. We also provide stainless steel frames and clamps. One person can complete the installation in a single day.

 

Hot Tags: eliminator cooling tower, China eliminator cooling tower manufacturers, suppliers, factory

Inquiry
goTop

(0/10)

clearall