Hainan Haizhou Fluid Technology Co., Ltd.
  • Closed Type Cooling Tower

    Closed Type Cooling Tower

    Cooling Water Flow: 8–2,000 m³/h
    Min Dimensions (L×W×H): 1.3 m × 1.5 m × 2.25 m
    Max Dimensions: 13 m × 26 m × 9.5 m
    Fan Diameter: 0.8–12 m
    Fan Power: 0.75–270 kW
    Air...

    Add to Inquiry
  • Evaporative Type Condenser

    Evaporative Type Condenser

    Cooling Water Flow: 8–1,000 m³/h
    Dimensions (Min): 1.2 m × 2.6 m × 2.5 m
    Dimensions (Max): 9 m × 14.6 m × 7.2 m
    Fan Diameter: 0.8–6.5 m
    Fan Power: 0.75–115 kW
    Max Air...

    Add to Inquiry
  • Dry Wet Separated Closed Cooling Tower

    Dry Wet Separated Closed Cooling Tower

    Cooling Water Flow: 50–2,000 m³/h
    Dimensions (Min): 2.6 m × 5.7 m × 3.8 m
    Dimensions (Max): 13 m × 26 m × 9.5 m
    Fan Diameter: 1.8–12 m
    Fan Power: 6–270 kW
    Air Flow...

    Add to Inquiry
  • Dry Wet Integrated Closed Cooling Tower

    Dry Wet Integrated Closed Cooling Tower

    Cooling Water Flow: 50–2,000 m³/h
    Fan Diameter (Max): Up to 10 m
    Fan Power: 5–260 kW
    Max Air Flow: 2,720,000 m³/h
    Spray Pump: 3–27 kW × 2
    Inlet/Outlet Pipe: DN100 × 2...

    Add to Inquiry
  • Double Air Inlet Closed Cooling Tower

    Double Air Inlet Closed Cooling Tower

    Cooling Water Flow: 54 to 725 m³/h
    Coil Working Pressure: 1.0 MPa
    Spray Pump Pressure: 0.2-0.3 MPa
    Spray Pump Motor: 2.2 kW - 11 kW x 2 setup
    nlet/0utlet Pipe Size: DN100x2 to...

    Add to Inquiry
  • Cooling Tower Open Loop

    Cooling Tower Open Loop

    Cooling Water Flow: 36–6,000 m³/h
    Min Dimensions (L×W×H): 1.48 m × 3.06 m × 2.878 m
    Max Dimensions: 21.6 m × 20 m × 6.6 m
    Fan Diameter: 1.2–10.36 m
    Fan Power: 1.1–250...

    Add to Inquiry
  • Dry Wet Hybrid Cooling Tower

    Dry Wet Hybrid Cooling Tower

    Cooling Water Flow: 50–3,500 m³/h
    Dimensions (Min): 2 m × 2 m × 6.5 m
    Dimensions (Max): 15.9 m × 15.9 m × 17.5 m
    Fan Diameter: 4.7–10.36 m
    Fan Power: 45–280 kW
    Air...

    Add to Inquiry
  • Concrete Counter Flow Industrial Cooling Tower

    Concrete Counter Flow Industrial Cooling Tower

    Cooling Water Flow: 1,000–6,000 m³/h
    Dimensions (Min): 8.8 m × 8.8 m × 9.9 m
    Dimensions (Max): 21.6 m × 21.6 m × 20 m
    Fan Diameter: 4.7–10.36 m
    Fan Power: 37–250...

    Add to Inquiry
  • Industrial Open Cooling Tower

    Industrial Open Cooling Tower

    Cooling Water Flow: 36–6,000 m³/h
    Min Dimensions (L×W×H): 1.48 m × 3.06 m × 2.878 m
    Max Dimensions: 21.6 m × 20 m × 6.6 m
    Fan Diameter: 1.2–10.36 m
    Fan Power: 1.1–250...

    Add to Inquiry
  • No Fill Spray Cooling Tower

    No Fill Spray Cooling Tower

    Cooling Water Flow: 80–1,000 m³/h
    Dimensions (Min): 2.6 m × 2.6 m × 4.4 m
    Dimensions (Max): 9 m × 9 m × 8 m
    Fan Diameter: 1.8–5.5 m
    Fan Power: 3–37 kW
    Air Flow Range:...

    Add to Inquiry
  • Cooling Tower Air Inlet Louvers

    Cooling Tower Air Inlet Louvers

    Blade Angle: 30–45°
    Blade Spacing: 25–50 mm
    Air Speed (design): 2.5 m/s
    Pressure Drop: ≤15 Pa
    Splash Block Rate: >99.99%
    Water Escape Rate: ≤0.0005%

    Add to Inquiry
  • Cooling Tower Fan Stacks

    Cooling Tower Fan Stacks

    Diameter Range: 600 mm to 5,000 mm
    Material Options: FRP, Galvanized Steel, Stainless Steel
    FRP Weight: ~1/3 of steel
    Efficiency Gain: 8–12%
    Motor Power Saving:...

    Add to Inquiry
First 123 Last 1/3
goTop

(0/10)