Dry Wet Integrated Closed Cooling Tower
Cooling Water Flow: 50–2,000 m³/h
Fan Diameter (Max): Up to 10 m
Fan Power: 5–260 kW
Max Air Flow: 2,720,000 m³/h
Spray Pump: 3–27 kW × 2
Inlet/Outlet Pipe: DN100 × 2 to DN300 × 8
Save Water in Hot and Dry Areas
Our Dry Wet Integrated Closed Cooling Tower is ideal for dry regions where water is scarce. The unit operates in two modes: in hot weather, it uses both wet and dry cooling; in colder conditions, it switches to dry mode only, using almost no water. It handles standard AC applications (37 °C in / 32 °C out) as well as high-temperature jobs (85–60 °C in / 45–35 °C out). Water flow ranges from 50 m³/h up to 2,000 m³/h, making it suitable for large factories and central AC plants. The structure is robust, with major components available in FRP, stainless steel, Galvalume, or concrete.

Smart Control of Air and Water
This is not a simple combination of two systems. The tower uses a smart linkage: the dry section features finned tubes that pre-cool the air or assist the wet section, reducing water lost to evaporation. The fan can be as large as 10 m in diameter, with power ranging from 5 kW to 260 kW, and airflows reaching 2,720,000 m³/h. This allows one Dry Wet Integrated Closed Cooling Tower to replace multiple smaller towers, saving space and piping costs. Noise is well-controlled, with three levels available. The super low noise type operates at just 50 dB(A) at 1 m, even at full fan speed.

An Award-Winning, Trusted Partner
Our company has received multiple recognitions: "Jiangxi Gazelle Enterprise" (2020), "Specialized and Innovative SME" (2021), and "Patent Demonstration Enterprise in Ji'an City" (2023). These awards demonstrate our expertise. By choosing our Dry Wet Integrated Closed Cooling Tower, you gain a reliable partner. We provide comprehensive pre-sale support: our engineers assess your site, processes, and local climate, then perform heat balance calculations for you. Remote monitoring is also available to track tower performance and provide early warnings. A 1-year warranty is included, with options for extended coverage.



Product Specifications
|
Parameter |
Details |
|
Cooling Water Flow |
50–2,000 m³/h |
|
Fan Diameter (Max) |
Up to 10 m |
|
Fan Power |
5–260 kW |
|
Max Air Flow |
2,720,000 m³/h |
|
Spray Pump |
3–27 kW × 2 |
|
Inlet/Outlet Pipe |
DN100 × 2 to DN300 × 8 |
|
Max Operating Weight |
Over 118 t |
|
Noise (Super Low) |
50 dB(A) at 1 m |
|
Coil / Spray Pressure |
1.0 MPa / 0.2–0.3 MPa |
|
Frame Material Options |
FRP, Stainless Steel, Galvalume, Concrete |
FAQ
Hot Tags: dry wet integrated closed cooling tower, China dry wet integrated closed cooling tower manufacturers, suppliers, factory