Hainan Haizhou Fluid Technology Co., Ltd.
Dry Wet Hybrid Cooling Tower

Dry Wet Hybrid Cooling Tower

Cooling Water Flow: 50–3,500 m³/h
Dimensions (Min): 2 m × 2 m × 6.5 m
Dimensions (Max): 15.9 m × 15.9 m × 17.5 m
Fan Diameter: 4.7–10.36 m
Fan Power: 45–280 kW
Air Flow Range: 55,000–2,970,000 m³/h

Send Inquiry
Description
Finned Tubes for Dual Benefits

Our Dry Wet Hybrid Cooling Tower features a front section with finned tubes that pre-condition the air before it reaches the wet spray zone. In summer, the fins reduce the heat load on the wet section, saving water. In winter, they suppress fog formation. This innovative design works for medium heat (43 °C/33 °C) and high heat (60 °C/35 °C) applications. Water flow ranges from 50 m³/h to 3,500 m³/h. By pre-cooling or pre-heating the air, this tower achieves 20–35% water savings-higher than standard fog-control towers.

product-800-800

 

Taller Design for Enhanced Heat Exchange

 

This tower is taller than the basic model to accommodate the finned tube section. Fins are made of aluminum or a copper-aluminum mix, providing a large surface area for efficient pre-cooling. Fan diameters range from 4.7 m to 10.36 m, with power from 45 kW to 280 kW. Airflow spans 55,000 to 2,970,000 m³/h. Spray pump setup remains the same (2.2–58 kW × 2) with pipe sizes DN100–DN500 × 2. Noise levels follow our three standards: normal (64–78 dB(A)), low (55–75 dB(A)), and super low (50–70 dB(A)), allowing quiet operation without sacrificing performance.

 

Award-Winning Green Technology

 

The Jiangxi government recognized this tower with the "Energy Saving and Emission Reduction Technology Demonstration" award. Our R&D team holds 57 patents, including 13 inventions. Pre-sale, we provide detailed site analysis, including weather, water quality, and heat balance calculations. Post-sale, we offer training, spare parts, and remote monitoring to provide early warnings and ensure smooth operation.

 

Product Specifications

 

Parameter

Details

Cooling Water Flow

50–3,500 m³/h

Dimensions (Min)

2 m × 2 m × 6.5 m

Dimensions (Max)

15.9 m × 15.9 m × 17.5 m

Fan Diameter

4.7–10.36 m

Fan Power

45–280 kW

Air Flow Range

55,000–2,970,000 m³/h

Spray Pump

2.2–58 kW × 2

Pipe Size

DN100–DN500 × 2

Operating Weight

6,521–82,490 kg

Water Savings

20–35%

Fin Material

Aluminum or Copper-Aluminum

Noise Options

64–78 / 55–75 / 50–70 dB(A)

 

FAQ

 

Can this tower operate in extremely cold regions like Siberia?

Yes. At temperatures below -10 °C, the finned section nearly eliminates visible white plume, ensuring no fog even in harsh northern climates.

 

Hot Tags: dry wet hybrid cooling tower, China dry wet hybrid cooling tower manufacturers, suppliers, factory